BWNF-GE-S55L-80D
1.25G 1550 nm 80 km SFP Transceiver, Duplex LC — BWNF-GE-S55L-80D
BWNF-GE-S55L-80D is the proposed order code for a 1.25G SFP configuration with a stated 1550 nm transmitter, nominal 80 km single-mode reach, duplex LC interface, and digital diagnostics. Every configuration and performance value requires confirmation against the approved BWNFiber datasheet, drawing, and test limits before quotation or publication.

Product Value Summary
BWNF-GE-S55L-80D is the proposed order code for a 1.25G SFP configuration with a stated 1550 nm transmitter, nominal 80 km single-mode reach, duplex LC interface, and digital diagnostics. Every configuration and performance value requires confirmation against the approved BWNFiber datasheet, drawing, and test limits before quotation or publication.
Short Answer for Buyers
If the approved product record confirms a duplex dual-fiber interface, deploy one compatible transceiver at each end of the link and use two single-mode fiber strands: one transmit and one receive. Do not approve the link from the 80 km label alone. Confirm the exact host, rate/protocol, channel loss, receiver-overload boundary, fiber/connector path, temperature grade, and required documents.
Light CTA: Send the host model and route-loss estimate for an exact-configuration review. [CTA destination: TBC — verify the production RFQ URL/form.]
Proposed Key Features — Source Approval Required
- Form factor: SFP — TBC — approved datasheet required
- Nominal data rate: 1.25 Gb/s — TBC — rate/protocol table required
- Transmit wavelength: 1550 nm — TBC — approved optical specification required
- Nominal reach: 80 km over single-mode fiber — TBC — conditions and optical budget required
- Optical interface: duplex LC — TBC — drawing required
- Digital diagnostics: TBC — implemented fields and calibration evidence required
- Commercial / industrial temperature options: TBC — exact order-code mapping and qualification required
Technical Specification Verification Matrix
| Attribute | Value in supplied draft | Publication status | Required proof |
|---|---|---|---|
| Part number | BWNF-GE-S55L-80D | TBC | Approved product master / datasheet |
| Form factor | SFP | TBC | Datasheet / drawing |
| Data rate | 1.25 Gb/s | TBC | Supported-rate/protocol table |
| Transmitter | 1550 nm DFB | TBC | BOM / optical specification |
| Receiver | PIN-TIA | TBC | BOM / optical specification |
| Connector | Duplex LC | TBC | Mechanical drawing |
| Fiber | Single-mode; draft says OS2 | TBC | Approved media and reach conditions |
| Nominal reach | 80 km | TBC | Qualification and optical budget |
| Tx center wavelength | Draft: 1500–1580 nm, 1550 nm typical | TBC | Datasheet and test method |
| Tx average power | Draft: −5 to 0 dBm | TBC | Datasheet and production limits |
| Extinction ratio | Draft: minimum 8.2 dB | TBC | Datasheet and test method |
| Rx wavelength | Draft: 1260–1620 nm | TBC | Datasheet and test method |
| Rx sensitivity | Draft: maximum −26 dBm | TBC | BER condition and test method |
| Rx overload | Draft: maximum −3 dBm | TBC | Datasheet and test method |
| Supply | Draft: 3.13–3.47 V | TBC | Electrical specification |
| Supply current | Draft: maximum 300 mA | TBC | Electrical specification |
| Power | Draft: maximum 1.0 W | TBC | Electrical specification |
| Operating temperature | Draft: 0–70 °C; −40–85 °C optional | TBC | Exact order codes and qualification |
| Storage temperature | Draft: −40–85 °C | TBC | Qualification / datasheet |
| Humidity | Draft: 5–85%, non-condensing | TBC | Qualification / datasheet |
| DOM/DDM | Draft: yes | TBC | EEPROM/readout and calibration record |
| Compliance | Draft: SFP MSA, SFF-8472, IEEE 802.3z, RoHS | TBC | Current declarations and qualification evidence |
Interface and Fiber Configuration
The supplied draft describes a duplex LC interface over single-mode fiber. If confirmed, the link uses separate transmit and receive strands. Confirm the port drawing, connector polish, approved patch-cord type, fiber specification, cleaning/inspection procedure, and permitted adapter path before public release.
Do not publish LC/UPC OS2 required until the drawing and engineering guidance confirm both polish and fiber requirements.
How Many Modules and Fibers Are Required?
| Item | Conditional requirement | Evidence gate |
|---|---|---|
| Transceivers | One compatible module at each end of the link | Exact-host and module-revision approval |
| Fiber strands | Two strands for a duplex dual-fiber link | Confirmed duplex interface drawing |
| Wavelength pairing | Matching dual-fiber modules normally use the approved same product class at both ends; no complementary BiDi pair is implied | Approved link/application guide |
| Patch cord | Duplex LC single-mode assembly, polish and fiber grade TBC | Drawing and engineering approval |
This section replaces the incorrect source FAQ answer “No.”
Link-Budget and Receiver-Overload Approval
Nominal reach is not a route guarantee. After the optical limits are approved, evaluate both boundaries:
- Maximum channel loss: minimum transmit power minus receiver sensitivity, less applicable penalties and engineering margin.
- Minimum channel loss: maximum transmit power minus receiver overload. A low-loss route may require an approved attenuation plan if received power would exceed the receiver limit.
The supplied draft values would imply preliminary arithmetic, but they are not approved and must not be published or used for route approval. Supply the route length, fiber type, connector/adaptor count, splice count, measured loss if available, and engineering margin for review.
Compatibility and Application Conditions
Do not use a generic brand list as proof of compatibility. Supply the exact switch, router, NIC, transport shelf, or media-converter model and software/firmware version. BWNFiber should return one controlled status:
- Validated — exact host and module revision tested, with record ID.
- Coded, not host-validated — EEPROM profile prepared but exact platform not tested.
- Sample validation required — buyer must test before volume approval.
- Unsupported / unknown — no compatibility claim.
The supplied draft proposes Gigabit Ethernet, metro/access, and 1G Fibre Channel applications. These remain TBC — exact rate/protocol qualification required.
How to Select and Approve This Model
- Confirm the exact host equipment, port type, software/firmware, and permitted module coding.
- Confirm the required line rate and protocol; a form-factor match is not a complete compatibility statement.
- Confirm the opposite-end module and approved link architecture.
- Build the route loss from fiber length, connectors, adapters, splices, and engineering margin.
- Compare both maximum channel loss and minimum channel loss against approved module limits.
- Confirm connector type, polish, patch-cord construction, and cleaning/inspection procedure.
- Select the exact temperature-grade order code.
- Define required DOM fields, thresholds, and acceptance method.
- Request the current datasheet, declarations, test limits, and traceability documents.
- Validate samples in the target hosts before a volume order when no exact compatibility record exists.
Differences from Related Products
| Related item | Difference under review | Buyer decision |
|---|---|---|
| Proposed BWNF-GE-S55L-40D | Same local family code with a 40 km label | Compare approved optical limits; do not substitute by distance alone |
| Proposed BWNF-GE-S55L-100D / 120D | Higher nominal reach labels in the local family | Choose only from approved budget, dispersion, overload, and host conditions |
| Proposed 160/180/200 km variants | Local drafts indicate different receiver/laser classes at longer reach | Require exact approved datasheets and architecture |
| 1.25G BiDi SFP | Uses one fiber with complementary Tx/Rx wavelengths | Do not confuse simplex BiDi pairing with a duplex two-fiber link |
| 100BASE 1550 nm 80 km SFP | Different line rate and protocol | Confirm 1.25G/1G application; search results can mix 100M and 1G products |
Testing and Quality-Control Requirements
The public page must not claim that BWNFiber performs a specific test until the product owner supplies the controlled method and acceptance limits. Request confirmation of:
- Transmit wavelength, spectral width, and average optical power.
- Receiver sensitivity and overload with the applicable BER/test pattern.
- Extinction ratio and eye-mask requirement.
- Link-budget and dispersion conditions for the nominal reach.
- DOM/DDM readout, calibration, alarms, and thresholds.
- Supply current and power consumption.
- Temperature qualification for each order code.
- Host coding and exact-host validation status.
- Visual/label inspection and serial/lot traceability.
Current status: TBC — method, equipment, sampling plan, limits, and report format required.
Packaging and Procurement Information
The supplied draft does not verify MOQ, price, stock, lead time, warranty, packaging, label, country of origin, HS code, or document-pack contents. Keep these fields quotation-specific.
Information Required for an RFQ
- Quantity and delivery destination.
- Exact host manufacturer, model, port, and software/firmware version.
- Required line rate and protocol.
- Opposite-end module part number and revision.
- Fiber type, route length, connector/adapter/splice count, measured or estimated route loss, and margin.
- Required connector polish and patch-cord type.
- Operating temperature range.
- DOM/DDM and alarm-threshold requirements.
- Coding, label, and private-label requirements.
- Required datasheet, drawing, declaration, test report, and traceability documents.
- Sample-validation plan and volume-approval criteria.
Downloads — Withhold Until Approved
| Document | Status |
|---|---|
| Product datasheet | TBC — approved revision required |
| Mechanical/interface drawing | TBC — approved revision required |
| Optical/electrical test limits | TBC — controlled document required |
| Compatibility matrix | TBC — host-level records required |
| RoHS or other declaration | TBC — current signed declaration required |
| Sample/shipment test report | TBC — scope, lot, and serial mapping required |
Frequently Asked Questions
Do I need two transceivers for a duplex 80 km link?
Yes, if the approved product record confirms a duplex two-fiber interface: one compatible transceiver is required at each end. Unlike a single-fiber BiDi pair, the two ends do not rely on complementary Tx/Rx wavelength directions. Confirm both module revisions and hosts before ordering.
Does an 80 km label guarantee an 80 km route?
No. Nominal reach is not route approval. Verify approved transmit power, receiver sensitivity and overload, fiber/connector/splice loss, dispersion conditions, penalties, and engineering margin.
Can this long-reach SFP be used on a short link?
Not automatically. A low-loss route can exceed the receiver-overload limit. Calculate the minimum required channel loss from approved product values and use only an engineering-approved attenuation plan.
Is this module 1000BASE-ZX?
The supplied draft uses the 1000BASE-ZX class label. Publish that nomenclature only after the approved BWNFiber datasheet and conformity wording are reviewed. Do not treat the label alone as a complete 80 km engineering specification.
Is the receiver PIN or APD?
The supplied draft says PIN-TIA. This remains TBC until the approved datasheet or BOM confirms the receiver type.
Does the module support DOM/DDM?
The supplied draft says yes. Public copy requires an approved datasheet or EEPROM/readout record showing the implemented parameters, calibration status, alarms, and thresholds.
Is an industrial-temperature version available?
The draft lists an optional −40 °C to +85 °C grade. Do not order or publish it until BWNFiber confirms the exact order code and qualification record.
Is it compatible with my switch or router?
Compatibility is host-model and software/firmware specific. Send the exact platform details. EEPROM coding alone does not prove full functional validation.
Which patch cord is required?
The draft states duplex LC and OS2, but connector polish and approved fiber/patch-cord requirements remain TBC pending the interface drawing and engineering guidance.
Which documents should be approved before a volume order?
Request the current datasheet, drawing, exact-host validation status, applicable declarations, controlled test limits, and the agreed sample/shipment report.
What should a sample-approval plan cover?
Define target hosts and firmware, rate/protocol, opposite-end module, fiber route or test setup, optical power and DOM checks, traffic/BER acceptance, temperature requirements, and document review.
RFQ CTA
Request an exact-configuration review
Send the host model, software/firmware, line rate/protocol, opposite-end optic, route loss, temperature grade, quantity, and required documents. BWNFiber can then return a controlled status: validated, coded-only, sample validation required, or unsupported/unknown.
CTA link/form: TBC — verify the production contact or RFQ destination before CMS mapping.