SFP-Family & XFP Transceivers, up to 25G

1.25G 1000BASE-SX SFP, 850 nm, 550 m, DOM, Duplex LC

Specification-only sentence

SFP-Family & XFP Transceivers, up to 25G BWNF-GE-M85L-05D Configuration Review

BWNF-GE-M85L-05D

What this 1000BASE-SX SFP is for

This page is for buyers validating one exact 1G short-reach optical module, not for choosing among the full SFP product family. The intended use is a duplex multimode Gigabit Ethernet link between compatible SFP ports. It is not a 1310 nm LX optic, a single-fiber BiDi module, or a 25G SFP28 module.

Before release, confirm six items: host model and software version, far-end optic, fiber grade, installed link length, connector and polish, and operating temperature. A generic brand name does not prove platform compatibility.

Key features under review

  • SFP form factor and 1.25 Gb/s working data-rate description.
  • 1000BASE-SX working application designation.
  • 850 nm VCSEL transmitter and PIN receiver: TBC — source required.
  • Duplex LC optical interface: TBC — source required.
  • Multimode-fiber reach up to 550 m: TBC — source required for the exact fiber-grade conditions.
  • Digital optical monitoring / DOM: TBC — source required for the implemented SFF-8472 fields and calibration type.
  • Maximum power of 1.0 W: TBC — source required.
  • Commercial and industrial temperature variants: TBC — source required.

Working technical specifications

The table below preserves values from the supplied internal page draft. It is a review table, not an approved datasheet.

ParameterWorking valueRelease status
Part numberBWNF-GE-M85L-05DInternal SKU mapping verified
Form factorSFPVerify against approved datasheet
Nominal data rate1.25 Gb/sVerify against approved datasheet
Ethernet application1000BASE-SXVerify standards declaration
Nominal wavelength850 nmVerify against approved datasheet
Transmitter / receiverVCSEL / PIN-TIATBC — source required
Optical connectorDuplex LCTBC — source required
Fiber mediumMultimode fiberVerify supported fiber grades
Rated reachUp to 550 mVerify fiber grade, modal bandwidth, and channel conditions
Digital diagnosticsDOM / DDMVerify monitored values and calibration
Maximum power1.0 WTBC — source required
Commercial case temperature0 °C to +70 °CTBC — source required
Industrial case temperature−40 °C to +85 °C, optionalTBC — source required
Standards / complianceIEEE 802.3z, SFP MSA, SFF-8472, RoHSTBC — declaration or report required

Do not publish the draft optical-power, sensitivity, overload, LOS, humidity, supply-voltage, or electrical-amplitude tables until the approved BWNFiber datasheet identifies the test conditions, units, tolerances, and applicable temperature grade.

Fiber and link requirements

A duplex 1000BASE-SX link uses two fiber strands: one for transmit and one for receive. It also needs one compatible optical transceiver at each endpoint. The far-end module must match the Ethernet application, wavelength class, fiber type, and link direction.

The 550 m figure must not be applied to every multimode plant without checking the fiber specification. Industry references show that allowable 1000BASE-SX distance varies with core size and modal bandwidth. For this BWNFiber model, publish a fiber-grade reach table only after the approved datasheet confirms the supported OM1/OM2/OM3/OM4 conditions.

Do not approve the link from jacket color alone. Read the cable print legend or test record, confirm the connector at both ends, and compare total channel conditions with the module specification.

How to confirm host compatibility

Provide the exact host manufacturer, equipment model, port type, and software or firmware version. BWNFiber should return the proposed EEPROM code and the evidence used for that platform. A list of brand names without exact host models or test records is not a compatibility matrix.

Use this sequence:

  1. Confirm that both endpoints support 1G operation in an SFP port.
  2. Record the exact host models and software versions.
  3. Confirm the far-end optic and fiber plant.
  4. Select the required temperature grade.
  5. Review the approved datasheet and any available compatibility record.
  6. Validate a sample in the target port before a material batch order when platform acceptance is critical.

How this model differs from related optics

RequirementUse this pageUse another product page
1G, 850 nm, duplex MMF, short reachBWNF-GE-M85L-05D, after specification approval—
1G, 1310 nm, duplex SMFNo1000BASE-LX/LX10-class model
One fiber strandNoMatched BiDi pair with opposite Tx/Rx wavelengths
10G short-reach MMFNo10GBASE-SR SFP+ model
25G short-reach MMFNo25GBASE-SR SFP28 model

The exact related SKU links must be added only after their canonical product URLs are confirmed.

Applications

Potential applications include in-building Gigabit Ethernet switch, router, NIC, or media-converter links over an approved multimode path. The original draft also lists 1G Fibre Channel; keep that application blocked until the datasheet confirms the supported line rates and protocol coding.

Testing and quality-control evidence required

Before publication or batch approval, attach or reference the model-specific records that exist for this SKU. Do not claim a test was performed unless the record is available.

Evidence itemRequired status
Approved product datasheet with revision dateRequired
Optical transmitter and receiver limits with test conditionsRequired
DOM/DDM field and calibration statementRequired
Commercial / industrial variant mappingRequired if both grades are offered
RoHS or other compliance declarationRequired before making the claim
Host coding or compatibility recordRequired for any named platform claim
Sample functional test recordRecommended for a new host combination
Label, packaging, and serial/lot traceability definitionTBC — source required

Packaging and procurement information

MOQ, price, stock, lead time, warranty, country of origin, packaging, and label options are TBC — source required. Quote them for the requested configuration and destination instead of presenting them as fixed catalog facts.

Required information for an RFQ

Send:

  • Quantity and destination country.
  • Exact host manufacturer and equipment model at each end.
  • Port type and software or firmware version.
  • Far-end transceiver model.
  • Installed fiber grade and core size, if known.
  • Link length, patch panels, and connector type at both ends.
  • Required operating-temperature grade.
  • Required EEPROM code, label, packaging, and documentation.
  • Sample or batch-test requirement.

Primary CTA: Send the host models, fiber grade, link length, quantity, and temperature requirement to request the approved datasheet, compatibility review, and quotation.

Datasheet, drawing, and test-report area

  • Product datasheet: TBC — source required
  • Mechanical drawing: TBC — source required
  • DOM/DDM definition: TBC — source required
  • Compliance declaration: TBC — source required
  • Compatibility or sample-test record: available only for the reviewed host/configuration
FAQ

Frequently asked questions

Do I need two transceivers?

Yes. A normal duplex optical link needs one compatible transceiver at each endpoint. The cable path also needs two fiber strands, with one carrying each transmit direction. This module should not be paired with a single-fiber BiDi optic.

What fiber is required?

Use multimode fiber that is approved for the required 1000BASE-SX distance. Confirm the fiber grade, core size, modal bandwidth, installed length, and connector path. Do not approve the link from cable color alone.

Is 550 m available on every multimode fiber grade?

No universal claim should be made. Industry distance limits vary by fiber characteristics. The exact reach table for BWNF-GE-M85L-05D is TBC — source required until the approved datasheet is supplied.

Can I use OM3 or OM4 fiber?

The current internal draft lists OM2/OM3, but exact supported grades and reach need datasheet confirmation. A higher-grade cable does not authorize a longer published reach unless the module and channel specification support it.

Is DOM included?

The working product record says yes. Confirm the implemented monitored values, calibration method, alarm thresholds, and host display behavior in the approved datasheet.

Will this SFP work in my switch?

Compatibility depends on the exact equipment model, port, software version, and EEPROM code. Send those details for review. A generic brand list is not sufficient evidence.

Is this the same as a 1000BASE-LX SFP?

No. SX is an 850 nm multimode application. LX-class optics use a different optical specification and require a different link review.

Can this module be used for 1G Fibre Channel?

TBC — source required. The original draft lists 1G Fibre Channel, but the supported line-rate range and compliance statement must be verified first.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.