Product value summary
This proposed BWNFiber product is a flat FTTx drop cable built around a PBT loose tube, G.657.A2 single-mode fiber, two FRP strength members and a black HDPE sheath. The supplied internal draft lists a nominal cable profile of 4.1 × 8.5 mm, but the approved model, supported fiber-count range and application limits still require source confirmation.
Short answer for buyers: Use this page to identify the exact cable construction and prepare an RFQ. Do not approve it by the family name alone. Confirm the fiber count, conductor status, installation route, mechanical load case, reel plan, cable marking and required evidence against the released datasheet and drawing.
Primary CTA: Send the installation route, required fiber count, total quantity and reel length to request a configuration review and quotation.
Key configuration — provisional
| Field | Provisional value | Release status |
|---|---|---|
| Fiber count | TBC — source conflict: 1–12F vs 2–12F | Blocked |
| Fiber type | G.657.A2 | Confirm against released datasheet |
| Cable form | Flat, central loose tube | Confirm against drawing |
| Loose tube | One PBT tube; provisional 2.4 mm OD and 0.35 ± 0.05 mm wall | Engineering review required |
| Tube water blocking | Tube-filling compound | Confirm material/BOM |
| Strength members | Two FRP members; provisional 1.6 mm diameter each | Confirm against drawing/BOM |
| Sheath | Black HDPE | Confirm grade and application rating |
| Nominal cable size | (4.1 × 8.5) ± 0.5 mm | Confirm orientation and tolerance |
| Approximate cable weight | 40 kg/km | Confirm applicable count/configuration |
| Metallic trace wire | TBC — not stated in supplied table | Must be explicitly confirmed |
| Product model | TBC — source required | Blocked |
What this construction does — without overclaiming
- The loose tube contains the fibers and is listed as PBT in the supplied internal draft.
- Two FRP members are listed on either side of the cable structure. Because FRP is non-metallic, the BOM must separately confirm whether any other metallic component or trace wire is present.
- The supplied record lists tube-filling compound and an HDPE sheath. It does not establish a fire rating, direct-burial rating, rodent resistance, UV test result or named standards compliance.
- G.657.A2 identifies a bend-insensitive single-mode fiber category. It does not, by itself, define the minimum installation bend radius of the finished cable.
Optical characteristics — engineering release required
The V4 source contains a flattened multi-wavelength table. do not use for order release a reconstructed value map until the original table is reviewed. The final table must keep each value paired with its wavelength, condition, unit and whether it applies to uncabled fiber or cabled fiber.
| Parameter | Required publication format | Status |
|---|---|---|
| Attenuation coefficient | One row per wavelength and state; include dB/km | TBC — original column alignment required |
| Cable cut-off wavelength | Value + unit + method/reference | Provisional ≤ 1260 nm; verify |
| Zero-dispersion wavelength | Range + unit | Provisional 1300–1324 nm; verify |
| Zero-dispersion slope | Value + corrected unit formatting | Provisional ≤ 0.092 ps/(nm²·km); verify |
| PMD | Define coefficient/statistical basis and unit | Provisional value requires engineering review |
| Mode-field diameter | Wavelength + range + unit | Provisional 8.5–9.3 μm at 1310 nm; verify |
| Macrobending result | Radius, turns, wavelength and unit | TBC — do not call it the finished-cable bend radius |
Mechanical and environmental limits — provisional
| Parameter | Supplied provisional value | What must be confirmed |
|---|---|---|
| Maximum span | 65 m | Wind/ice/loading class, sag, hardware, route and design basis |
| Tensile load | 1,350 N | Short-term/installation/long-term condition and test method |
| Operating temperature | −25°C to +70°C | Finished-cable qualification and standard/method |
| Storage/transport temperature | −25°C to +70°C | Finished-cable qualification and packaging condition |
| Installation temperature | −25°C to +70°C | Installation method and minimum bend/tension limits |
These values are not a deployment design. An aerial route requires the project engineer to confirm span, environmental loading, support hardware, sag and local requirements. Duct, wall and buried routes require their own suitability evidence.
How to select and approve the configuration
- Define the route. State whether the cable is for aerial, duct, wall/facade or another path. Do not combine route assumptions.
- Confirm the exact count. Resolve the 1–12F versus 2–12F source conflict and name the selected count.
- Confirm the BOM. Identify G.657.A2 fiber, PBT tube, filling compound, dual FRP members, HDPE sheath, ripcord/water-blocking elements and any metallic trace component.
- Confirm mechanical limits. Match tensile, span, crush, bend and temperature limits to stated test conditions.
- Approve the drawing. Check the cross-section, dimensions, tolerances, component positions and cable marking.
- Approve the reel plan. Match fiber count, ordered length and permissible length per drum to a specific packing row.
- Approve the evidence pack. Require the released datasheet, drawing and agreed inspection/test documents before bulk order release.
Differences from related BWNFiber pages
| Page/product | Use it when | Do not confuse it with this draft |
|---|---|---|
| FTTH Drop Cable category | Comparing multiple constructions and routes | The category owns broad selection intent. |
| Loose Tube Flat Toneable Drop Cable | A locatable cable with a stated 24 AWG copper trace wire is required | It lists G.657.A1 and a different 4.0 × 10.2 mm profile. |
| 12/24 Cores Loose Tube Flat Drop Cable | A 12F or 24F G.652.D configuration from that family is required | It has different dimensions and count structure. |
| Aerial Self-support FTTH Drop Cable | The published self-supporting family matches the aerial design | Do not transfer its LSZH, messenger or test claims to this product. |
Intended use and compatibility boundaries
The supplied record identifies FTTH subscriber connections as the intended application. Exact aerial, duct, wall, direct-burial, indoor and transition-route eligibility is TBC — source required. Connectorized compatibility is also TBC because no connector, terminal, clamp, closure or pre-terminated assembly is specified.
Before approval, state:
- installation route and environment;
- required fiber count and fiber grade;
- cable-entry and clamp dimensional limits;
- whether a trace wire is required;
- maximum pulling load and bend control used by the installer;
- termination/splicing method and closure or terminal interface;
- local fire, building, utility and project requirements.
Packaging and procurement information
The internal draft contains one packing row for GJYFXTBY 2C–12C with a 4,000 m drum and drum dimensions D 900 mm, d 400 mm, B 550 mm and b 500 mm. This row is not approved as a universal packing claim. BWNFiber must confirm the model name, covered counts, tolerance, net/gross weight, drum material and whether shorter or project-specific reel lengths are available.
MOQ, price, stock, lead time, warranty, export packaging, Incoterms and delivery commitments: TBC — quotation/source required.
What to include in an RFQ
- approved product name/model or a request for model matching;
- installation route and environment;
- required fiber count and G.657.A2 confirmation;
- total cable quantity and preferred length per drum;
- non-toneable or toneable requirement;
- cable size and hardware interface limits;
- mechanical and temperature requirements with test conditions;
- cable sheath color and marking text;
- destination country and delivery destination;
- required datasheet, drawing, packing list, inspection plan and test records;
- sample/pre-production approval requirement;
- any project-specific standard or customer specification.
Document download and evidence area
| Document | Page status | Release requirement |
|---|---|---|
| Approved product datasheet | TBC — source required | Must carry the final model/count/revision |
| Cross-section drawing | TBC — source required | Must reconcile every image label and dimension |
| Mechanical/environmental test evidence | TBC — source required | Must identify method, sample, condition, limit and result |
| Fiber optical specification | TBC — source required | Must preserve wavelength/value alignment |
| Packing drawing / reel matrix | TBC — source required | Must map count/configuration to reel length and dimensions |
| Certification/compliance documents | TBC — source required | Add only documents applicable to this exact model and market |
CTA
Request a configuration and evidence review
Send BWNFiber the installation route, fiber count, total length, reel length, conductor requirement, destination and required project documents. BWNFiber should return the matched model, approved datasheet/drawing and quotation after the open technical fields are confirmed.
